HXAPF Active Power Filter


HXAPF active power filter is accessed to grid with parallel hybrid. Through checking and analyzing harmonic wave and reactive current of nonlinear load, offset current is injected into the power grid to offset harmonic wave and reactive current brought by load. This is a kind of dynamic and flexible harmonic wave suppression and reactive power compensation solutions.

Product introduction


Technical Features:
1. DSP+CPLD digital control; response time <10ms
2. Advanced major circuit topology and control algorithm, with higher precision and stability
3. Modular design, convenient for manufacturing debugging
4. Multifunctional touch screen, to intelligently monitor operation status and parameters of power grid
5. Convenient parallel hybrid, to increase capacity
6. Perfect bridge arm overcurrent and protection function
7. Convenient to use, and easy to operate and maintain



Technical Parameters:
Mode of Connection
3-phase 3-wire or 3-phase 4-wire
Input Voltage
3×380V±10%
Input Frequency
50Hz±2%
Dynamic Compensation Response Time
Complete Response Time<10ms
Switching Frequency
16kHz
Function Set
Only Compensating Harmonic Wave, Only Compensating Reactive Power, Compensating both Harmonic Wave and Reactive Power; Free Switch of Manual and Automatic Operation
Harmonic Compensation Times
2-25 Times
Protection Mode
DC Overvoltage IGBT Overcurrent Device Temperature Protection
Overload Protection
Automatic current limiting at setting value, no overload
Cooling Mode
Intelligent Air Cooling
Noise Level
<65db (in the Cabinet and operated at rated conditions)
Ambient Temperature
-10℃ ~ +45℃
Ambient Humidity
<85%RH, no condensation
Installation Site
Indoor
Altitude
≤1000m (reducing capacity upon higher altitude)
Wiring Method
Incoming and Outgoing Lines both at Upper Part
IP Code
IP20
Intelligent Communication Interface
Add-on Module
Remote Monitoring
Optional
Dimension (mm)
(W X D X H)
30A
60A
75A
100A
600 X 500 X 1500
600 X 500 X 1500
600 X 500 X 1800
800 X 600 X 2200
Weight (kg)
3-Phase 4-Wire
3-Phase 3-Wire
30A, 50A
75A, 100A
30A, 50A
75A, 100A
280
360
240
290
Remark:
1. Compensating current can be determined through actual test data, or measured through power system details (single line drawing, transformer, load condition, etc.)
2. 3-wire system should be configured with 2 or 3 CT (used for phase A and phase C), and 4-wire system should be configured with 3 CT (used for phase A, phase B and phase C)